Key Features
- Optional Din mounting clamp
- Light weight corrosion resistant aluminum enclosure
- Compact in size – Lowest footprint
- High shock and vibration resistance for harsh environmental conditions
- Input surge protection
- Overvoltage / Overcurrent / Over Temperature/ Short Circuit Protections
- Low output ripple
- Input noise filters for EMI
- > 3 KV input-output Isolation
Application
- Industrial control and automation
- Home automation
- Security system
- Lighting system
- Embedded systems
- Medical instruments
Product line
MODEL | PEPD60-12-5 | PEPD60-24-5 | |
SPECIFICATION | 12V-4A / 5V-2A | 24V-2A / 5V-2A | |
DATASHEET | |||
I N P U T | VOLTAGE RATING | 90V - 270VAC | |
FREQUENCY | 45Hz TO 55Hz | ||
DC VOLTAGE RANGE | 100V - 300VDC | ||
AC CURRENT RANGE @ 110VAC | 0.783A | 0.783A | |
AC CURRENT RANGE @ 230VAC | 0.380A | 0.380A | |
INRUSH CURRENT @ 110VAC | < 12A | < 12A | |
INRUSH CURRENT @ 230VAC | < 30A | < 30A | |
NO LOAD POWER (Typ.) | 0.223W | 0.223W | |
POWER FACTOR @ 110VAC | > 0.69 | > 0.69 | |
POWER FACTOR @ 230VAC | > 0.65 | > 0.65 | |
INTERNAL FUSE | 2A SLOW ACTING | ||
EFFICIENCY (Typ.) | > 85% | > 85% | |
O U T P U T | RATED VOLTAGE / CURRENT - O/P 1 | 12V / 4A | 24V / 2A |
RATED VOLTAGE / CURRENT - O/P 2 | 5V / 2A | 5V / 2A | |
ADJ. RANGE | 11V-14V (O/P 1 ONLY) | 22V-26V (O/P 1 ONLY) | |
LINE REGULATION | < 1% | < 1% | |
LOAD REGULATION | < 1% | < 1% | |
RIPPLE (20MHz BANDWIDTH) | < 150mV | < 150mV | |
START-UP TIME | 10ms | 10ms | |
HOLD-UP TIME | 12ms | 12ms | |
O T H E R S | SHORT-CIRCUIT PROTECTION | YES (Individual O/P) | |
OVER-LOAD PROTECTION | YES (Individual O/P) | ||
OVER TEMP. PROTECTION | YES (Individual O/P) | ||
WITHSTAND VOLTAGE (IN – OUT1) | > 3KV for 1 min | ||
WITHSTAND VOLTAGE (IN – OUT2) | > 2.5KV for 1 min | ||
WORKING TEMPERATURE | -25°C to 75°C | ||
COOLING METHOD | Natural air convection | ||
DIMENSIONS (L x W x H) | 119mm x 87mm x 52mm | 119mm x 87mm x 52mm | |