switch mode power supply

Key Features

  • Optional Din mounting clamp
  • Light weight corrosion resistant aluminum enclosure
  • Compact in size – Lowest footprint
  • High shock and vibration resistance for harsh environmental conditions
  • Input surge protection
  • Overvoltage / Overcurrent / Over Temperature/ Short Circuit Protections
  • Low output ripple
  • Input noise filters for EMI
  • > 3 KV input-output Isolation

Application

  • Industrial control and automation
  • Home automation
  • Security system
  • Lighting system
  • Embedded systems
  • Medical instruments

Product line


MODEL

PEPT70-12-(-12)-5

PEPT70-15-(-15)-5

PEPT70-12-(-12)-24

PEPT70-15-(-15)-24

SPECIFICATION

12V-2A / (-12V)-2A / 5V-2A

15V-2A / (-15V)-2A / 5V-2A

12V-2A / (-12V)-2A / 24V-0.6A

15V-2A / (-15V)-2A / 24V-0.6A

DATASHEET

I

N

P

U

T

VOLTAGE RATING

90V - 270VAC

FREQUENCY

45Hz TO 55Hz

DC VOLTAGE RANGE

100V - 300VDC

AC CURRENT RANGE @ 110VAC

0.783A

0.783A

0.783A

0.783A

AC CURRENT RANGE @ 230VAC

0.380A

0.380A

0.380A

0.380A

INRUSH CURRENT @ 110VAC

< 12A

< 12A

< 12A

< 12A

INRUSH CURRENT @ 230VAC

< 30A

< 30A

< 30A

< 30A

NO LOAD POWER (Typ.)

0.223W

0.223W

0.223W

0.223W

POWER FACTOR @ 110VAC

> 0.69

> 0.69

> 0.69

> 0.69

POWER FACTOR @ 230VAC

> 0.65

> 0.65

> 0.65

> 0.65

INTERNAL FUSE

  2A SLOW ACTING

EFFICIENCY (Typ.)

> 85%

> 85%

> 85%

> 85%

O

U

T

P

U

T

RATED VOLTAGE / CURRENT - O/P 1

12V / 2A

15V / 2A

12V / 2A

15V / 2A

RATED VOLTAGE / CURRENT - O/P 2

-12V / 2A

-15V / 2A

-12V / 2A

-15V / 2A

RATED VOLTAGE / CURRENT - O/P 3

5V / 2A

5V / 2A

24V / 0.6A

24V / 0.6A

ADJ. RANGE

-

-

-

-

LINE REGULATION

< 1%

< 1%

< 1%

< 1%

LOAD REGULATION

< 1%

< 1%

< 1%

< 1%

RIPPLE (20MHz BANDWIDTH)

< 120mV

< 120mV

< 120mV

< 120mV

START-UP TIME

10ms

10ms

10ms

10ms

HOLD-UP TIME

6ms

6mss

6ms

6ms

O

T

H

E

R

S

SHORT-CIRCUIT PROTECTION

YES (Individual O/P)

OVER-LOAD PROTECTION

YES (Individual O/P)

OVER TEMP. PROTECTION

YES (Individual O/P)

WITHSTAND VOLTAGE (IN – OUT)

> 3KV for 1 min

WITHSTAND VOLTAGE (O/P 1 – O/P 3)

> 2.5KV for 1 min

WORKING TEMPERATURE

-25°C to 75°C

COOLING METHOD

Natural air convection

DIMENSIONS (L x W x H)

130mm x 88mm x 52mm

130mm x 88mm x 52mm

130mm x 88mm x 52mm

130mm x 88mm x 52mm

WEIGHT

460gms

460gms

460gms

460gms